Section 4 Component Teardown
4-34
Condenser Removal
To remove the condenser:
1. Disconnect power supply from unit.
2. Remove the front panel and cabinet wrapper/sleeve.
3. Extract the three screws from each side of the
condenser securing the left and right side condenser
bracket to the condenser. (See Figure 4-81)
4. Attach an approved self tapping line tap valve to the
process tube. Connect refrigerant recovery system
to tap valve. Turn on recovery system, open the
line tap valve, and allow refrigerant to flow into an
approved tank.
5. Disconnect inlet and outlet lines from condenser.
6. Extract the two screws securing the bottom of the
condenser to the unit base. (See Figure 4-87)
7. Carefully lift the condenser out from the unit base.
Evaporator Removal
To remove the evaporator:
1. Disconnect power supply from unit.
2. Remove the front panel and cabinet wrapper/sleeve.
3. Remove the control box assembly with power cord
and thermistors.
4. Remove the front scroll housing adapter from above
the evaporator. Extract the two screws on each side
of the evaporator securing the mounting bracket to
the unit partition. (See Figure 4-88)
5. Attach an approved self tapping line tap valve to the
process tube. Connect refrigerant recovery system
to tap valve. Turn on recovery system, open the
line tap valve, and allow refrigerant to flow into an
approved tank.
6. Disconnect inlet and outlet lines from evaporator.
7. Carefully lift the evaporator out from the unit base.
Figure 4-87.
Screws
Figure 4-88.
Evaporator
Mounting Screws
Blower Housing
Scroll
Front
Scroll
Housing
Adapter