Section 2 Installation
2-11
Installation Instructions
For Slider Casement Air Conditioners
These instructions describe installation in a typical wood
framed window with a wood slide-by sash, or installation
in a metal casement window. Modification may be
necessary when installing in windows made differently
than those shown in these instructions.
A high window accessory kit (Part# EA103W) is available
for window heights up to 62” (1575mm).
Meeting Electrical Requirements
Observe all local governing codes and ordinances.
Do not, under any circumstances, remove the power
supply cord grounding prong.
If codes permit, and a separate grounding wire is
used, it is recommended that a qualified electrician
determine that the grounding path is adequate and not
interrupted by plastic, non-metallic gaskets, or other
insulating materials.
NOTE
ELECTRICAL GROUND IS REQUIRED FOR THIS
APPLIANCE.
DO NOT GROUND TO A GAS LINE.
IF COLD WATER PIPE IS INTERRUPTED BY
PLASTIC, NON-METAL GASKETS, OR OTHER
INSULATING MATERIALS, DO NOT USE FOR
GROUNDING.
CHECK WITH A QUALIFIED ELECTRICIAN IF
THERE IS DOUBT ABOUT THE APPLIANCE BEING
PROPERLY GROUNDED.
DO NOT MODIFY THE POWER SUPPLY PLUG. IF
THE POWER SUPPLY OUTLET IS WRONG, HAVE
ONE INSTALLED BY A QUALIFIED ELECTRICIAN.
DO NOT HAVE A FUSE IN THE NEUTRAL OR
GROUNDING CIRCUIT. A FUSE IN THE NEUTRAL
OR GROUND CIRCUIT COULD RESULT IN
ELECTRICAL SHOCK.
DO NOT USE AN EXTENSION CORD WITH THIS
APPLIANCE.
FAILURE TO FOLLOW THESE INSTRUCTIONS
COULD RESULT IN ELECTRICAL SHOCK, SERIOUS
INJURY OR DEATH.
WARNING
Receptacle Wiring
Receptacle wiring should be a minimum or 14 gauge.
Use copper wire only. If a mating 3-prong grounding-
type wall receptacle is not available, it is the responsibility
of the consumer to have a properly grounded 3-prong
wall receptacle installed by a quali ed electrician.
Electrical Requirements
A 115 volt (103.5V minimum, 126.5V maximum), 60
Hertz, AC only, 15 ampere fused electrical supply is
required. A time delay fuse or time delay circuit
breaker is also required. A separate circuit, serving
only this appliance, MUST be provided by the customer.
Recommended Grounding Method
For your personal safety, this appliance must be
grounded. The air conditioner includes a power supply
cord with a 3-prong grounding plug.
To minimize possible electrical shock hazard:
1. Cord must be plugged into a mating 3-prong
grounding-type wall receptacle,
2. Must be grounded in accordance with National
Electrical Code (ANSI/NFPA 70- latest version) and
3. All local codes and ordinances must be followed.