Section 2 Installation
2-20
8,000-12,000 BTU Thru-The-Wall
Installation Instructions
For Existing Sleeve
Note that the air conditioner dimensions are: 24” wide,
14-1/2” high, and 18-1/2” deep (without front). Install air
conditioner according to these installation instructions
to achieve the best performance.
Items in the Thru-The-Wall Kit
You may not need all parts in the kit. Discard unused
parts.
Part Description Qty.
Tapered Spacer Blocks ..................... 17” Long ........ 2
Centering/Support Blocks ...4-½”x 3-½”x 1-½” ......... 2
Plastic Divider ...................” x 4-½”x 14-½” ........ 1
Stuffer Seal .............................1”x 1-½ “x 84” ........ 1
Seal ...............................1-½”x 1-½”x 26-½” ........ 2
Seal ................................... 1-½”x 1-½”x 14” ........ 2
Seal ..................................1-½”x ”x 26-½” ........ 2
Seal ...................................... 1-½”x ”x 14” ........ 2
Seal ..........................................1” x ¾”x 14” ........ 1
Trim Frame (side legs) ............................................. 2
Trim Frame (top & bottom legs) ............................... 2
Ground Wire (green) ............................................... 1
Nut for grounding screw .......................................... 1
Grounding Screw ..................................................... 1
Grille (plastic) ......................................................... 1
Nuts (plastic) .......................................................... 4
Screw w/washer ...................................................... 4
How to Install
Wall Sleeve Dimensions
Width Height Depth
25-1/2” 15-1/4” 16”, 17-1/2” or 22”
2. Remove old Air Conditioner from wall sleeve and
prepare wall sleeve as follows:
a. Clean interior (do not disturb seals).
b. Wall sleeve must be securely fastened in wall
before installing Air Conditioner. Drive more nails
or screws through sleeve into wall if needed.
c. Repair paint if needed.
3. If not existing, drill a 3/16” clearance hole for
grounding screw through left side of wall sleeve in
a clear area about 3 inches maximum (to suit) back
from front edge of sleeve as shown in Figure 2-61.
Next attach ground wire inside sleeve, using
grounding screw and nut. Pull loose end of ground
wire out front of sleeve and temporarily bend it
down and around lower edge of sleeve.
4. Prepare the wall sleeve for installation of the new
unit per the following instructions.
Frigidaire 16”+ 17-12” Deep
Frigidaire 22” Deep
5.
Install new unit into wall sleeve.
6. To attach ground wire to the new unit, remove the
screw from the left side front.
7. Assemble and install the Trim Frame.
Rear
Unit
Front
Level
1/4” to 5/16”
Sleeve
Wall
Wall Sleeve To Unit
Sleeve Grounding
3"
Max.
3
/
16
"
Hole
1"
Figure 2-60.
All wall sleeves used to mount a new Air Conditioner
must be in sound structural condition and have a rear
grille that securely attaches to sleeve, or rear flange
that serves as a stop for the Air Conditioner.
NOTE
When installation is complete, replacement unit MUST
have a rearward slope as shown in Figure 2-60.
CAUTION
Figure 2-61.
Vista de página 49