Section 2 Installation
2-1
Models FAA, FAC and FAX Room Air
Conditioner Installation Instructions
Model FAA, FAC and FAX air conditioners are designed
to install in standard double hung windows with opening
widths of 23 to 36 inches (584 mm to 914 mm)
(See Figure 2-1)
Lower sash must open suf ciently to allow a clear vertical
opening of 14-1/4” inches (356 mm). The FAX series
only requires a 13” (330 mm) vertical opening. Side
louvers and the rear of the RAC unit must have clear air
space to allow enough air ow through the condenser for
heat removal. The rear of the unit must be outdoors, not
inside a building or garage.
Mounting Hardware Tools Needed
3/4” Screws Qnty 7 Phillips Screwdriver
Lock Frame Qnty 2 Drill (For pilot holes)
Sash Lock Qnty 1
Before installing unit, the top rail must be assembled on
the unit.
Top Rail Hardware Tool Needed
3/8” Screw Qnty 4 Phillips Screwdriver
Top Rail Qnty 1
1. Remove air conditioner from carton and place on a
flat surface.
2. Remove top rail from packaging material.
3. Align the hole in the top rail with those in the top of
the unit then secure with the 3/8” screws.
(See Figure 2-2)
How to Install
1. Place unit on floor, a bench or table. There is a
left and right window filler panel, be sure to use
the proper panel for each side. When installed, the
flange for securing the panel to the window sill will
be facing into the room.
A. Hold the accordion filler panel in one hand and
gently pull back the center to free the open end.
(See Figure 2-3)
B. Slide the free end (“I” section) of the panel into
the cabinet as shown in Figures 2-4, 2-5 and
2-6. Slide the panel down. Be sure to leave
enough space to slip the top and bottom of the
of the frame into the rails on the cabinet.
Exterior
Wall
Offset
Stool Sill
Interior
Wall
23” to 36”
584mm to 914mm
14-1/4”min.
(337mm)
Do not use any screws other than those specified here.
NOTE
For safety reasons, all four (4) screws must be securely
fastened.
NOTE
Top Rail and Sliding Panels at each side are offset to
provide the proper pitch to the rear of (5/16”). This is
necessary for proper condensed water utilization and
drainage. If you are not using the Side Panels for any
reason, this pitch to the rear must be maintained!
NOTE
When handling unit, be careful to avoid cuts from
sharp metal edges and aluminum fins on front and rear
coils.
CAUTION