Section 4 Component Teardown
4-24
Control Box Component Removal
(Heater Equipped Models)
The control box houses the control board, fan motor
capacitor, transformer and terminal block. The power
cord enters the control box along the left side and is
held in position with a grommet.
1. Disconnect the power supply from unit.
2. Remove front panel and cabinet wrapper/sleeve.
3. Extract the two screws from the left side and the
screw at the top right rear corner securing the cover
to control box. Remove cover from unit.
(See Figure 4-61)
4. Discharge capacitor.
To remove power cord:
5. Extract the two screws securing the power cord to
the bottom front of the unit tray.
6. Disconnect black wire from terminal block.
7. Disconnect white wire from control board.
8. Extract ground screw securing green wire to the rear
of the control box. (See Figure 4-62)
To remove terminal block:
9. Disconnect wire leads from fan motor capacitor.
10. Extract screw securing fan motor capacitor to right
side wall of control box. (See Figure 4-62)
To remove fan motor capacitor:
11. Disconnect all wire leads from terminal block.
12. Extract screw securing terminal block to bottom of
control box. (See Figure 4-62)
To remove transformer:
13. Disconnect wire leads from transformer at control
board.
14. From rear of control box, extract the screws securing
transformer to control box. (See Figure 4-62)
To remove thermistors:
15. Remove any wire retainers securing the thermistor
wire leads. Disconnect thermistor leads at control
board and remove from unit.
Figure 4-61.
To discharge the high voltage capacitor, wait for 60
seconds and then short-circuit the connection of the
high-voltage capacitor (that is the connecting lead of
the high-voltage rectifier) against the chassis with the
use of an insulated screwdriver.
CAUTION
Cover
Screws
Control
Box
Screws
Figure 4-62.
Screws
1 of 2
Shown
Ground
Screw
Fan Motor
Capacitor
Control
Board
Transformer
Terminal
Block
Control
Box
Screw
Screw
To remove the control board:
16. Disconnect all wire leads from control board. Label
as needed for proper reconnection.
17. Compress the plastic retainers securing the control
board to the front of the control box and remove
from unit.
Control Box Removal
To remove the control box:
1. Disconnect the power supply from unit.
2. Remove front panel and cabinet wrapper/sleeve.
3. Remove control box cover.
4. Remove wire ties and disconnect the compressor,
condenser fan motor and electric heater wire leads
from the control box components.
5. Extract the screw from the floor of the control box
securing the assembly to the unit frame. Extract the
screw from the top right corner and the screw from
the lower left rear corner. (See Figure 4-62)
6. Carefully pull control box off of the unit.