3. Using a socket spanner 7 unscrew and
remove the nozzles replacing them with
the ones required for the kind of gas in
use (see table " Burner characteristics " ).
AC
B
If changing to gas G2.350, after nozzle
replacement (letter B), cover the nozzle
with air regulator. For semi-rapid and
auxiliary burner use air regulator marked
as A (dimension 10). For rapid burner
use air regulator marked as C (dimen-
sion 16).
4. Reassemble the parts following the same
procedure backwards.
5. Replace the rating label (placed near the
gas supply pipe) with the relevant one for
the new type of gas supply. You can find
this label in the package of the injectors
supplied with the appliance.
These burners do not need any primary air
regulation.
Adjustment of minimum level
To adjust the minimum level of the burners,
proceed as follows:
1. light the burner;
2. turn the knob on the position of minimum
flame;
3. remove the knob;
4. with a thin screwdriver, adjust the bypass
screw;
If changing from natural gas G20 20
mbar to liquid gas G30/31 37 mbar,,
completely tighten the adjustment screw
in, until a small regular flame is obtained.
If changing from liquid gas G30/31 37
mbar to natural gas G20 20 mbar, undo
the by-pass screw about 1/2 of a turn.
If changing from natural gas G20 20
mbar to natural gas G2.350 13 mbar un-
do the by-pass screw about 1/4 of a
turn.
If changing from liquid gas G30/31 37
mbar to natural gas G2.350 13 mbar,
undo the by-pass screw about 3/4 of a
turn.
Reassemble the parts following the same
procedure backwards.
Finally, check the flame does not go out
when quickly turning the knob from the max-
imum position to the minimum position.
Electrical connection
The unit is preset to work with a voltage of
single phase 230 V.
Before making the connection make sure
that:
• the energy power available in the user's
house is sufficient for the normal supply of
this appliance (see rating plate)
• the unit is correctly connected to earth
through a suitable plug and according to
the installation country Laws
• the socket or the omnipolar switch used
for the connection must be easilv reached
with the installed appliance
The appliance is supplied with electric cable,
therefore you will have to fit it with a standard
plug, suitable for the total electric load shown
electrolux 21