electrolux 31
Adaptation to different kinds of gas
To adapt the appliance to a different kind of
gas from the one the appliance has been set for,
follow the instructions below in their order.
Gas connection
LPG: use the rubber pipe holder «D».
Natural gas : use the pipe holder «E».
Always insert the gasket sealing «B». Then
proceed with the gas connection, as indicated in
the relevant paragraphs.
Hob burners nozzles
1. Nozzles replacement
1. Remove the pan supports.
2. Extract the caps and the wall baffles of the
burners.
3. Using a socket spanner 7 unscrew and
remove (see diagram) the nozzles replacing
them with the ones required for the kind of
gas in use (see table “Burner characteris-
tics”).
4. Reassemble the parts following the same
procedure backwards.
5. Replace the rating label (placed near the gas
supply pipe) with the relevant one for the
new type of gas supply. You can find this
label in the package of the injectors supplied
with the appliance.
These burners do not need any primary air
regulation.
2. Adjustment of minimum level
To adjust the minimum level of the burners,
proceed as follows:
1. light the burner;
2. turn the knob on the position of minimum
flame;
3. remove the knob;
4. with a thin screwdriver, adjust the by-pass
screw (see diagram).
If changing from natural gas 20 mbar/13
mbar to liquid gas, completely tighten the
adjustment screw in, until a small regular
E
B
D
A
A Gas connection point
B Gasket
C Adjustable connection
D LPG rubber pipe holder
E Natural gas pipe holder
C
Vista de página 30