to avoid any stress to the unit. Gas feeding
pipe fitting is Gc 1/2. For this type of
installation, connection to the gas supply
should be carried out using only and
exclusively flexible metallic tubes in
conformity with rules in force.
Connection using flexible non metal
pipes
When the connection can be easily
inspected in its full extent, there is the chance
to use a flexible pipe according to the rules
in force. The flexible pipe must be tightly fixed
using clamps according to the rules in force.
The flexible pipe should be made ready
for use in such a way that:
- nowhere it can reach overtemperature,
other than room temperature, higher than
30°C; if the flexible pipe, to reach the cock,
must run behind the range, it must be
installed as shown in the diagram;
- it is no longer than 1500 mm;
- it shows no throttles;
- it is not subject to traction or torsion;
- it does not get in touch with cutting edges
or corners;
- it can be easily inspected in order to check
its condition.
The control of preservation of the flexible
pipe consists in checking that:
- it doesn't show cracks, cuts, marks of
burnings both on the end parts and on its
full extent;
- the material is not hardened, but shows
its normal elasticity;
- the fastening clamps are not rusted;
- expiry term is not due.
If one or more abnormalities are seen, do
not repair the pipe, but replace it.
IMPORTANT
Once installation is complete, check the
perfect seal of every pipe fitting, using
a soapy solution, never a flame.