9.3 Other technical data
TOTAL POWER:
Gas original: G20/G25 (2E+) 20/25 mbar = 7,7 kW
Gas replacement: G30 (3+) 28-30 mbar = 545 g/h
G31 (3+) 37 mbar = 536 g/h
G130 (1c) 8 mbar = 7,5 kW
Electric supply: 220-240 V ~ 50/60 Hz
Appliance category: III1c2E+3+
Gas connection: G 1/2"
Appliance class: 3
9.4 Gas burners for NATURAL GAS G20/G25 20/25 mbar
BURNER NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
1/100 mm
Rapid 2,7 0,75 130
Semi-rapid 1,9 0,45 96
Auxiliary 1,0 0,33 70
9.5 Gas burners for LPG G30/G31 28-30/37 mbar
BURNER NORMAL
POWER
kW
MINIMUM
POWER
kW
INJECTOR
MARK 1/100
mm
NOMINAL GAS FLOW g/h
G30 28-30
mbar
G31 37 mbar
Rapid 2,7 0,75 86 196 193
Semi-rapid 1,9 0,45 71 138 136
Auxiliary 1,0 0,33 50 73 71
9.6 Gas burners for TOWN GAS G130 8 mbar
BURNER NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
Rapid 2,7 0,75 240
Semi-rapid 1,9 0,45 195
Auxiliary 1,0 0,33 127
ENGLISH 17