RANGEHOOD INSTALLATION (CONT) RANGEHOOD INSTALLATION (CONT)
If additional or alternative mounting points are required
there are 4 x M10 threaded mounting points on the top of
the hood as highlighted in the image below.
Model A B C D1 D2 D3 D4 D5 D6
ERHC938S 366mm 46mm 500mm 750mm 700mm 650mm 600mm 787mm
485mm
ERHC1238S 366mm 46mm 900mm 975mm 925mm 875mm 825mm 1085mm 485mm
WARNING!
Failure to install the screws or fixing device in
accordance with these instructions may result in
electrical hazards.
4. Prior to installing the hood into position, x exhaust
transition duct using screws supplied, ensuring the
seal is between the rangehood top panel and the
base of the exhaust transition (Fig. D).
4a. If required, t the dampers and secure with clamps,
duct tape or cable ties.
Transition pieces
ERHC1238S - 1200mm model
Transition piece
screw holes (4 places)
Top of
cooker
Screws are to
be tightened
after the hood
is mounted on
the wall
Fig. D
Fig. B
Mounting
points
Anti-tilt
points
Min - See table
19mm max diameter
4mm
9mm max diameter
Max - See table
Rangehood
mounting point
detail
Mounting
screw detail
20
10
15
Fig. C
5. Mounting and securing the transition pieces is shown
in Fig. D.
WARNING!
Use screws provided to secure transition piece at
preformed holes. Using alternate screws and hole
locations may cause an electricl safety risk.
6. Hang hood on the mounting screws, tighten mounting
screws then secure at the anti-tilt locations as
indicated in Fig. B.
WARNING!
Due to product weight, take appropriate measures
to lift and position the product to avoid injury.
7. The canopy rangehood has been supplied with duct
transition piece/s, 200mm diameter non-combustible
ue pipe must be used with the transition piece/s.
Continue the centre line to the ceiling. Fit preferred
ue pipe to the fan transition duct (Fig. D1 & D2,
see page 11).
Use worm drive clamps, cable ties or suitable duct tape to
secure exible pipe to the transition duct.
NOTE: We recommend extending flue pipe through the
roof to external roof cowl to vent exhaust externally.
We do not recommend venting into ceiling cavity.
NOTE: To ensure optimum performance of the
rangehood, the use of 200 mm diameter rigid ducting is
recommended. The use of bends should be avoided.
Rigid flexible ducting is suitable, although loose flexible
ducting is unacceptable. All ducting must be fire retardant.
Electrical connection
Check that the installation complies with the standards
of local building, gas and electrical authorities. Before
connecting to the mains supply ensure that the mains
voltage corresponds to the voltage on the rating plate
inside the rangehood.
A
D1
D2
D3
D4
C
B
D5
D6
M10