Electrolux EHS8675P Manual do Utilizador Página 25

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 36
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 24
25
1 Safety Instructions for
the Installer
A device must be provided in the electrical installa-
tion which allows the appliance to be disconnected
from the mains at all poles with a contact opening
width of at least 3 mm.
Suitable isolation devices include line protecting
cut-outs, fuses (screw type fuses are to be re-
moved from the holder), earth leakage trips and
contactors.
In respect of fire protection, this appliance corre-
sponds to EN 60 335-2-6. This type of appliance
may be installed with a high cupboard or wall on
one side.
Drawers may not be fitted underneath the hob.
The installation must guarantee shock protection.
The kitchen unit in which the appliance is fitted
must satisfy the stability requirements of
DIN 68930.
For protection against moisture, all cut surfaces
are to be sealed with a suitable sealant.
On tiled work surfaces, the joints in the area where
the hob sits must be completely filled with grout.
On natural, artificial stone, or ceramic tops, the
snap action springs must be bonded in place with
a suitable artificial resin or mixed adhesive.
Ensure that the seal is correctly seated against the
work surface without any gaps. Additional silicon
sealant must not be applied; this would make re-
moval more difficult when servicing.
The hob must be pressed out from below when re-
moved.
Clean the cut-out area of the worktop.
Affix the one-sided adhesive sealing tape provided
around the entire underside of the hob top along
the outer edge of the ceramic glass plate. Be care-
ful not to stretch it. The interface should be posi-
tioned in the middle of one of the sides. After
trimming the tape (allow some extra mm), press
the two ends against each other.
For Australia:
CAUTION: The surface temperature exceeds 95°C.
To avoid a hazard, underbench access must be re-
stricted.
Supply cords must have a temperature rating not
less than 105°C.
Vista de página 24