BURNER RAPID SEMI-RAPID AUXILIARY
(large) (medium) (small)
POSITION MAX MIN MAX MIN MAX MIN
NOMINAL THERMAL 3.0 0.65 2.0 0.45 1.0 0.33
POWER (kW)
NOMINAL FLOW 0.286 0.062 0.190 0.043 0.095 0.031
RATE (m
3
/h)
NOZZLE REFERENCE 119 Adjust. 96 Adjust. 70 Adjust.
(1/100 mm)
NOMINAL THERMAL 2.8 0.65 2.0 0.45 1.0 0.33
POWER (kW)
NOMINAL FLOW 202 47 144 32 72 24
RATE (g/h)
NOZZLE REFERENCE 86 40 71 32 50 28
(1/100 mm)
Overall dimensions
Width: 580 mm.
Depth: 510 mm.
Cut out dimensions
Width: 560 mm.
Depth: 480 mm.
Ignition HT Spark
Spark Generator Ispra Control's BF 50046
230-240V 0.6 VA T 120
Spark Gap Fixed
Rear Left Burner (semi-rapid)
Heat Input 2.0 kW (6824 BTU/HR)
Front Left Burner (rapid)
Heat Input 3.0 kW Natural Gas (10236 BTU/HR)
2.8 kW LPG (9554 BTU/HR)
Rear Right Burner (semi-rapid)
Heat Input 2.0 kW (6824 BTU/HR)
Front Right Burner (auxiliary)
Heat Input 1.0 kW (3412 BTU/HR)
Burner Dia. Tap By-pass
1/100 mm
Auxiliary 28
Semi-rapid 32
Rapid 40
Aeration adjustment none
NATURAL
GAS
20 mbar
TYPE OF
GAS
Characteristics
LPG GAS
28-30/37
mbar
VALUE = 49.92 MJ/Kg
VALUE = 37.78 MJ/m
3
Ws - 50.7 MJ/ m
3
Supply connections
Gas: RC 1/2 inch (1/2 inch male)Rear right hand corner
Electric: 230-240V 50Hz supply, 3 core flexible cable
with non rewireable plug fitted with a 3 amp cartridge
fuse
Instructions for the Installer
Engineers technical data
APPLIANCE CLASS: 3
APPLIANCE CATEGORY: II2H3+
APPLIANCE GAS SUPPLY: Natural gas G20 / 20mbar