A. End of shaft with nut
B. Washer supplied with the appliance
C. Elbow supplied with the appliance
Connection to the gas supply should be
with either rigid or semi-rigid pipe, i.e.
steel or copper.
The connection should be suitable for
connecting to R 1/2 (1/2 BSP male
thread).
When the final connection has been
made, it is essential that a thorough leak
test is carried out on the hob and
installation.
Make sure that the main connection pipe
does not exert any strain on the hob.
If you use flexible metal pipes make sure
that they agree to ISO 10380 and ISO
10807 standards. Be careful they do not
come in touch with mobile parts or they
are not squeezed. Also be careful when
the hob is put together with an oven.
CAUTION!
It is important to install the
elbow correctly, with the
shoulder on the end of the
thread, fitted to the hob
connecting pipe.
CAUTION!
Failure to ensure the correct
assembly will cause leakage
of gas.
CAUTION!
Make sure that the gas
supply pressure of the
appliance obeys the
recommended values.
Rigid connection:
Carry out connection by using metal rigid
pipes (copper with mechanical end).
8.4 Electrical connection
• Do not pull the mains cable to
disconnect the appliance. Always pull
the mains plug (if applicable).
• The appliance must not be connected
with an extension cable, an adapter or
a multiple socket. There is a risk of
fire.
• Do not let the power cable to heat up
to a temperature of more than 90° C.
The cable should be guided by means
of clamps fixed to the side of the
cabinet, in order to avoid any contact
with the equipment beneath the
cooktop.
• Make sure that there is access to the
mains plug after the installation.
Electrical Requirements
Permanent electrical installation must
agree with the latest I.E.E. Regulations
and local Electricity Board regulations.
For your own safety the installation must
be done by a qualified electrician (e.g.
your local Electricity Board, or a
contractor who is on the roll of the
National Inspection Council for Electrical
Installation Contracting [NICEIC]).
The manufacturer refuses
to be held responsible, if
these safety measures are
not abided by.
Supply connections
This hob has to be connected to 220-240
V (~ 50/60 Hz ) electricity supply.
The hob has a terminal block which is
marked as follows:
• L — Live terminal
• N — Neutral terminal
• or E — Earth terminal
Before carrying out the connection, make
sure:
1. The limiter valve and the electrical
system can take the appliance load
(see the rating plate)
2. The supply system is equipped with
an efficient earth connection in
compliance with the current
standards and regulations
3. The outlet or omnipolar switch used
for connection is easily accessible
with the appliance installed.
www.electrolux.com14