8.4 Adjustment of minimum level
To adjust the minimum level of the
burners:
1. Light the burner.
2. Turn the knob on the minimum
position.
3. Remove the knob.
4. With a thin screwdriver, adjust the
bypass screw position (A).
A
5. If you change:
from natural gas G20/G25 20/25
mbar to liquid gas, fully tighten the
bypass screw in.
from liquid gas to natural gas
G20/G25 20/25 mbar, undo the
bypass screw approximately 1/4 of
a turn.
from natural gas G20/G25 20/25
mbar to town gas G130 8 mbar,
undo the bypass screw
approximately 3/4 of a turn.
from town gas G130 8 mbar to
natural gas G20/G25 20/25 mbar,
tighten the bypass screw
approximately 3/4 of a turn.
from liquid gas to town gas G130 8
mbar, undo the bypass screw
approximately 1 turn.
from town gas G130 8 mbar to
liquid gas, fully tighten the bypass
screw in.
WARNING!
Make sure the flame does not
go out when you quickly turn
the knob from the maximum
position to the minimum
position.
8.5 Electrical connection
Make sure that the rated voltage and
type of power on the rating plate agree
with the voltage and the power of the
local power supply.
This appliance is supplied with a mains
cable. It has to be supplied with a
correct plug which can hold the load
that the rating plate rates. Make sure
that you install the plug in a correct
socket.
Always use a correctly installed
shockproof socket.
Make sure that there is an access to
the mains plug after the installation.
Do not pull the mains cable to
disconnect the appliance. Always pull
the mains plug.
There is a risk of fire when the
appliance is in connection with an
extension cable, an adapter or a
multiple connection. Make sure that the
ground connection agrees with the
standards and regulations.
Do not let the power cable to heat up
to a temperature higher than 90° C.
Make sure that you connect
the blue neutral cable to the
terminal with a letter "N" on it.
Connect the brown (or black)
phase cable to the terminal
which has a letter "L". Keep
the phase cable connected at
all times.
8.6 Connection cable
To replace the connection cable use only
the special cable or its equivalent. The
cable type is: H05V2V2-F T90.
Make sure that the cable section is
applicable to the voltage and the working
temperature. The yellow / green earth wire
must be approximately 2 cm longer than
the brown (or black) phase wire.
8.7 Building In
min.
55 mm
min.
650 mm
560 mm
480 mm
min.
600 mm
30 mm