If the supply gas pressure is changeable
or different from the necessary pressure,
you must fit an applicable pressure
adjuster on the gas supply pipe.
8.4 Adjustment of minimum
level
To adjust the minimum level of the
burners:
1. Light the burner.
2. Turn the knob on the minimum
position.
3. Remove the knob.
4. With a thin screwdriver, adjust the
bypass screw position (A).
A
5. If you change:
from natural gas G20 20 mbar to
liquid gas, fully tighten the bypass
screw in.
from liquid gas to natural gas G20
20 mbar, undo the bypass screw
approximately 1/4 of a turn (1/2 of
a turn for Triple Crown burner).
WARNING!
Make sure the flame does
not go out when you quickly
turn the knob from the
maximum position to the
minimum position.
8.5 Replacing the power supply
cable
Use the same type of power supply
cable. This cable must be connected to
the terminal block following the diagram.
230V~
230V~
N
PE
L
If the power supply is
damaged it must be
substituted by a suitable
cable available in the after
sales service.
Connection to a good earth
wiring system is absolutely
essential. The manufacturer
accepts no responsibility for
any inconvenience caused
by failure to comply with this
rule.
If the power supply cable has to be
replaced, the gauge of the wires in the
new cable must be at least 0.75 mm² (3 x
0.75 cable), the earth wire (yellow-green)
must be at least 20 mm longer at the end
for connection to the appliance.
To replace the connection cable use only
the special cable or its equivalent. The
cable type is: H03V2V2-FT90.
Do not let the power cable to heat up to a
temperature higher than 90° C.
The cable must be replaced by a
qualified electrician, who must make the
mains connection as shown below.
L — brown
N — blue
— yellow-green
L N
20 mm
ENGLISH 13