Gas burners
BURNER
NOR-
MAL
POWER
RE-
DUC-
ED
POW-
ER
NORMAL POWER
NATURAL GAS
G20 (2H) 20 mbar
LPG
(Butane/Propane)
G30/G31 (3+)
28-30/37 mbar
kW kW
inj. 1/100
mm
m³/h
inj.
1/100
mm
G30
28–
30
mbar
G31
37
mb
ar
g/h g/h
Auxiliary 1.0 0.33 70 0.095 50 73 71
Rapid
2.9 (nat-
ural gas)
2.7
(LPG)
0.75 120 0.276 86 196 193
10. ENVIRONMENT CONCERNS
Recycle the materials with the symbol
. Put the packaging in applicable
containers to recycle it.
Help protect the environment and human
health and to recycle waste of electrical
and electronic appliances. Do not dispose
appliances marked with the symbol
with the household waste. Return the
product to your local recycling facility or
contact your municipal office.
ENGLISH 15
Comentários a estes Manuais