Vista de página 11
Bar
Copper pipe
Clamp handle
Red arrow mark
Cone
Yoke
Handle
Bar
"A"
C: Putting flare nut on
Remove flare nuts attached to indoor and
outdoor unit, then put them on pipe/tube
having completed burr removal (Note: It is not
possible to put them on after flaring work).
Flare nut
Copper tube
Fig.17
Fig.18
D: Flaring work
Firmly hold copper pipe in a die according
to the dimension shown in the table below.
Carry out flaring work using flaring tool as
shown below.
Caution
Align the center of the pipes.
Sufficiently tighten the flare
nut with fingers, and then tighten
it with a spanner and torque wrench
as shown.
Tightening Connection
Excessive torque can break nut
depending on installation conditions.
Fig.19
Indoor unit tubing Flare nut Pipings
Outer diam.
(mm)
A(mm)
Max.
Min.
6.35 (1/4) 1.3
0.7
9.53 (3/8)
1.6 1.0
1.8
1.0
12.7 (1/2)
1.8
1.0
Outer
diam.
Tightening
torque (kg.m)
Additional tightening
torque (kg.m)
16.0 (5/8)
2.4
2.2
7.5
8.0
5.0
5.5
3.0
3.5
1.6
2.0
11
REFRIGERANT PIPE CONNECTION
6.35 (1/4)
9.53 (3/8)
12.7 (1/2)
16.0 (5/8)