If you change from natural gas G20 20
mbar to liquid gas, fully tighten the ad-
justment screw in.
If you change from liquid gas to natural
gas G20 20 mbar, undo the by-pass
screw approximately 1/4 of a turn.
WARNING!
Make sure the flame does not go
out when you quickly turn the
knob from the maximum position
to the minimum position.
8.4 Electrical connection
Make sure that the rated voltage and
type of power on the rating plate agree
with the voltage and the power of the
local power supply.
This appliance is supplied with a mains
cable. It has to be supplied with a cor-
rect plug which can hold the load that
the rating plate rates. Make sure that
you install the plug in a correct socket.
Always use a correctly installed shock-
proof socket.
Make sure that there is an access to
the mains plug after the installation.
Do not pull the mains cable to discon-
nect the appliance. Always pull the
mains plug.
There is a risk of fire when the appli-
ance is in connection with an extension
cable, an adapter or a multiple connec-
tion. Make sure that the ground con-
nection agrees with the standards and
regulations.
Do not let the power cable to heat up
to a temperature higher than 90° C.
To prevent contact between the cable
and the appliance below the hob use the
clamps which are on the side of the cabi-
net.
A
A)
Rigid copper pipe or flexible pipe of
stainless steel
8.5 Replacement of the
connection cable
To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make
sure that the cable section is applicable to
the voltage and the working temperature.
The yellow/green earth wire must be ap-
proximately 2 cm longer than the brown
(or black) phase wire.
8.6 Building in
30 mm
55 mm
40-50 mm
min. 650 mm
490 mm
min. 450 mm
270 mm
If several 30 cm hobs are to be installed
side by side into the same cut out, an as-
sembly kit including a support side brack-
et and supplementary seals is available at
our Service Centres. The relevant installa-
tion instructions are supplied within the kit
package.
270
+1
mm
R 5mm
min.
55mm
490
+1
mm
12