13
INSTALLATION
Power limitation
In a few cases, it can happen that, depending on the
type of connection and the fusing of the supply line,
a power limitation may be necessary. It can then
also be used if a higher electricity supply tariff is in
force for peak power (peak current meter).
More detailed values can be taken from the table
below.
a) No power limiting (Fig. 12 - Switch position 0)
b) Power limit stage 1 (Fig. 12, Switch position
1)
Depending on the internal switching combinations
of the hot plates, and on the mains connection, the
maximum power is limited when using both front hot
plates simultaneously. There is no limitation on the
rear hot plates, or for a combination of these with
one of the two front hot plates.
c) Power limit stage 2 (Fig. 12, Switch position
2)
The maximum power is litmitd for any two hot plates.
If three or four plates are being used
simultaneously, the maximum power of all plates in
use is reduced correspondingly. The cooking time
can therefore be somewhat longer as a result of the
reduced power used.
pos.0
pos.1
pos.2
Digitronic
Connection Fuse Switch
position
400 V 3 N ~ 13 A 0
8 - 12 A 1
400 V 2 N ~ greater than/equal 13 A 0
230 V 3 ~ greater than/equal 23 A 0
18 - 22 A 1
14 - 17 A 2
230 V 2 ~ 26 A 0
21-25 A 1
16 - 20 A 2
230 V ~ greater than/equal 26 A 0
21 - 25 A 1
16 - 20 A 2
fig.12